HV Battery Contactor Seize Check

- 1076921-00-A Insulation Multimeter Fluke 1587 FC
SPECIAL TOOLS
Insulation Multimeter Fluke 1587 FC (1076921-00-A) |
Only technicians who have been trained in High Voltage Awareness are permitted to perform this procedure. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, "High Voltage Awareness Care Points" for additional safety information.
Make sure that the insulation multimeter and leads are capable of handling at least 500V DC.
Procedure
| 1 | Remove the penthouse cover. See Cover - Penthouse (Remove and Replace). | ||||||||||||||||||||
| 2 | Set the insulation multimeter to measure resistance, and touch the probe tips together. Caution: If the multimeter displays greater than 0.2 ohms, the leads are defective and must be replaced. Do not use defective leads.
| ||||||||||||||||||||
| 3 | Consider your next step: | ||||||||||||||||||||
![]() | 4 | Inspect the center of the insulator caps on top of the HV battery positive contactor terminals: | |||||||||||||||||||
| 5 | Set the multimeter to measure the DC voltage across both terminals of the HV battery positive contactor, either through the probing hole of the insulator caps or directly onto the terminals:
| ||||||||||||||||||||
| 6 | Set the multimeter to measure resistance, and then perform the following measurements:
| ||||||||||||||||||||
| 7 | Reinstall the HV battery positive contactor insulator caps, if they were removed earlier. | ||||||||||||||||||||
| 8 | If the HV battery negative contactor is also suspect to have seized, or there is uncertainty, go to step 9. Otherwise, return to the Vehicle Electrical Isolation Procedure. | ||||||||||||||||||||
![]() | 9 | Inspect the center of the insulator caps on top of the HV battery negative contactor terminals: | |||||||||||||||||||
| 10 | Set the multimeter to measure the DC voltage across both terminals of the HV battery negative contactor, either through the probing hole of the insulator caps or directly onto the terminals:
| ||||||||||||||||||||
| 11 | Set the multimeter to measure resistance, and then perform the following measurements:
| ||||||||||||||||||||
| 12 | Reinstall the HV battery negative contactor insulator caps, if they were removed earlier. | ||||||||||||||||||||
| 13 | Return to the Vehicle Electrical Isolation Procedure. |